BioClean Clearview™ Autoclavable Goggles (Thermoplastic Rubber) OPTICALLY CORRECT FOR CLEAR VISION Description BioClean Clearview™ Autoclavable Cleanroom Goggles have a super-soft thermoplastic rubber frame with upper and indirect lower ventilation system to provide exceptional wearer comfort. These goggles feature a toughened anti-scratch polycarbonate lens with propriety anti-fog technology for unrivaled clear vision. Provided non-sterile. To be autoclaved at 121°C/250°F for 30…
EZTest is a self-contained biological indicator for monitoring steam / flash steam, ethylene oxide, hydrogen peroxide, or propylene oxide sterilization. EZTest contains bacterial spores on a filter-paper carrier packaged within a small, thermoplastic culture tube. Inside the thermoplastic culture tube is a sealed-glass ampoule of specially-formulated soybean casein digest culture medium containing a color indicator which turns a dramatic yellow…
SterilAmp II is a compact, self-contained biological indicator for monitoring industrial steam (121°C) sterilization of liquids in small containers. SterilAmp II precisely integrates the process lethality. SterilAmp II contains a specially formulated culture medium that turns a dramatic yellow when spores grow. The SterilAmp II provides easy visual confirmation of sterilization within 48 hours, without the need for difficult and…
EZTest is a self-contained biological indicator for monitoring steam/flash steam, ethylene oxide, hydrogen peroxide, or propylene oxide sterilization. EZTest contains bacterial spores on a filter-paper carrier packaged within a small, thermoplastic culture tube. Inside the thermoplastic culture tube is a sealed-glass ampoule of specially-formulated soybean casein digest culture medium containing a color indicator which turns a dramatic yellow when spores…
MagnaAmp is a self-contained ampoule biological indicator ampoule for monitoring steam sterilization of liquids in ampoules, large containers, or washer sterilizers. The MagnaAmp biological indicator ampoules contains Geobacillus stearothermophilus spores and a specially-formulated culture medium that turns a dramatic yellow if spores grow. The MagnaAmp provides easy visual confirmation of sterilization within 48 hours, without the need for difficult and…
FEATURES Chemical indicator for radiation sterilization processes. Range> 1kGy (> 1 MRad). Circular form (12.7 cms. Diameter). No printed. Color change: Yellow not exposed to Red exposed. Shelf life: 2 years. APPLICATIONS Monitoring and Verification, radiation sterilization processes APPS offers the most complete and highest quality line in the world in biological and chemical indicators to ensure sterility assurance…
FEATURES Chemical indicator for radiation sterilization processes. Range> 1kGy (> 1 MRad). Shape table with printed circle 14mm x 14mm. Color change: Yellow not exposed to Red exposed. Shelf life: 2 years. APPLICATIONS Monitoring and Verification, radiation sterilization processes.
Manufactured from environmentally friendly cellulose material made from wood pulp, not petroleum – Eliminates skin sensitivity issues associated with oily residues inherent in plastic based wrappers. Highest BFE (bacterial filtration efficiency) Data Available / Highly Permeable (no wet packs) / Cost Effective Bacterial barrier to both airborne and waterborne contamination Outstanding liquid repellency – water, alcohol, iodine Exceptional tensile strength –…
The Bowie and Dick Test Packs verify the proper function of the sterilizers and should be used every day the sterilizer is used before the first load. They have the instructions for use, the recommended frequency and storage instructions printed on the box to facilitate the use and training of personnel. The sheet is easy to read and interpret. Meets…
Built-in internal/external process indicators that change color when exposed to a specific temperature Manufactured from medical grade paper with extra-wide chevron to protect against instrument breaching, thumb-notch for easy opening, 6 corner tack seals to prevent curling and other potential contaminants from entering pouch upon opening and a perforated fold to help ensure the adhesive strip forms an airtight seal Once…
(Pictured: Full length 9" Clear Face Shield and 3/4 length 7" Clear Face Shield) Optically clear, distortion-free wrap-around face shield. 1.5” Foam headband holds shield away from face; “floats” lightly on forehead, with no pressure on temples; vented for increased airflow. Protects mask and face from direct splatter; may prolong mask life. Sonically welded elastic headband for added strength. Anti-fog…
Convenient, economical way to package instruments/items – use only the length and width required Manufactured from medical grade paper; complete paper and film separation Blue tinted transparent film easily identifies compromise in film due to puncturing or tearing Easily visible color process indicators for Steam and EO sterilization Guide to Biological and Chemical Indicators
ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Provides all features of Isofluid® with addition of FogFree® strip on inner layer Not made with natural rubber latex Colors: Blue | Sapphire | Turquoise Quantity: 40/Box
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Provides all features of Isofluid® with addition of FogFree® strip on inner layer and optically clear distortion-free wrap around shield. Not made with natural rubber latex…
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Provides all features of Secure Fit® Isofluid with addition of FogFree® strip on inner layer Not made with natural rubber latex Color: Blue Quantity: 40/Box
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Provides all features of Secure Fit® Isofluid FogFree® with attached optically clear, distortion-free face shield. Not made with natural rubber latex Description: Blue | Quantity: 25/Box…
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Fluid resistant outer layer White tissue inner layer Extra-long aluminum nose piece Not made with natural rubber latex Description: Blue | Green | Lavender…
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard Fluid resistant outer layer White tissue inner layer Extra-long aluminum nose piece Not made with natural rubber latex Description: Blue | Lavender | Pink Quantity:…
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard White hypoallergenic inner cellulose layer Fluid resistant outer layer Extra-long aluminum nose piece Extra soft – will not lint, tear or shred Not made…
Ideal for procedures where low amounts of fluid, spray and/or aerosols are produced. ASTM LEVEL 1 Fluid resistance= 80 mmHg BFE > 95% at 3 microns PFE ≥ 95% at 0.1 micron DELTA P, mm H2O/cm2 < 4.0 Meets EN14683 Rating-Type II Standard White hypoallergenic inner cellulose layer Fluid resistant outer layer Extra-long aluminum nose piece Extra soft – will not lint, tear or shred Not made…
Indicated for use when treating patients with airborn diseases such as TB, Influenza or New Covid-19. MAXIMUM FILTRATION Meets EN 149:2001 FFP2 NR NIOSH approved N95 Respirator Meets guidelines for TB exposure control Resistance to penetration by synthetic blood: 160 mmHg PFE = 99.9% @ 0.1 micron Malleable nose and chin pieces Inner/outer fluid resistant layers Chin pocket construction Although…
Fluid Resistance= 80 mmHg BFE >98.4% at 3 microns PFE = 98.5% at 0.1 micron Delta P (breathability) <4.0 H2O/cm2 Flame Spread Class 1 Fluid resistant pink outer layer Soft white spunbound inner layer Measures 6-1/4" x 3-1/2"/15.875 x 8.89 cm Not made with natural rubber latex Description: Pink Quantity: 50/Box
Indicator tapes provide immediate identification of processed items while also securing sterilization packs. The chemical indicator lines will show a visual color change from beige to dark brown/black when exposed to the steam sterilization process. Color change indicator verifies exposure to sterilization process. Tapes are individually packaged in 60 yard rolls and available in multiple widths. Choice of natural or blue color crepe…
MesaStrip is a conventional paper strip biological indicator for monitoring steam, low temperature steam formaldehyde, ethylene oxide, dry heat, chlorine dioxide, and gamma radiation industrial sterilization processes. MesaStrip contains bacterial spores on a filter paper carrier sealed within a convenient, peel-open envelope.
MesaStrip is a conventional paper strip biological indicator for monitoring steam, low temperature steam formaldehyde, ethylene oxide, dry heat, chlorine dioxide, and gamma radiation industrial sterilization processes. MesaStrip contains bacterial spores on a filter paper carrier sealed within a convenient, peel-open envelope.
MesaStrip is a conventional paper strip biological indicator for monitoring steam, low temperature steam formaldehyde, ethylene oxide, dry heat, chlorine dioxide, and gamma radiation industrial sterilization processes. MesaStrip contains bacterial spores on a filter paper carrier sealed within a convenient, peel-open envelope. To use a MesaStrip, simply place the envelope inside a product or product package. This “inoculated package” is…
Air Removal Test Pack – Intended to evaluate the performance of the Air Removal (vacuum) system of Pre-Vacuum equipped Steam Sterilizers. Pre-assembled, disposable test pack. After exposure, unwrap pack and remove the indicator sheet for your records. 20 indicators/box Expires 3 years from date of manufacture. 510(k) notification and meets AAMI, EN-867-3 and ISO 11140 air removal test. Lead Free…
The convenient, economical way to package instruments/items – use only the length and width required Manufactured from medical grade paper; complete paper and film separation Blue tinted transparent film easily identifies compromise in film due to puncturing or tearing Easily visible color process indicators for Steam and EO sterilization Guide to Biological and Chemical Indicators
The first FDA-approved Bowie-Dick reusable test pack has test sheets numbered consecutively and can be used 25 times before disposal. There are also small-sized Bowie and Dick packages for better storage and less waste of material.
Contains 70% Ethyl Alcohol meeting CDC recommended guidelines* Contains Aloe Vera and Vitamin E to moisturize, condition and soften skin Quick drying, leaves no sticky residue After application, hands do not require rinsing Latex compatible—contains no lanolin or petroleum based emollients Nut and gluten-free *CDC 2002 Guideline for Hand Hygiene in Health-Care Settings, Vol. 51, No. RR-16 Description: 4…
Convenient, wall-mounted one-touch dispenser Dispenses a pre-measured amount to minimize waste Easily accommodates SaniTyze™ Hand Sanitizer 1000 mL pouch Description: Dispenser - Each 1000 mL Pouch - Each
Newly Released 1710 Smart-Well® Incubator The heart of the Smart-Read® Monitoring System, the 1710 Smart-Well® is a highly sophisticated monitoring tool that is intuitive and designed with the user in mind. The Smart-Well incubator is easy-to-configure with its simple touch-screen interface and color LCD display. The incubator can evaluate up to ten Smart-Read EZTest biological indicators independently, and contains an additional cell for…
The STEAMPlus Sterilization Integrator is an “advanced technology” medical device that provides a simple, accurate method of assuring that proper conditions for sterilization have been met during a sterilizer cycle. For use with all Steam processes (gravity, prevacuum and flash), the STEAMPlus has documented performance equivalent to a biological indicator. The STEAMPlus Sterilization Integrator is engineered to integrate the three…
Sterilization Bags of 100% Tyvek® with film HDPE high-density polyethylene in different sizes, compatible with sterilization by ethylene oxide, steam and gamma radiation that guarantees maximum steam penetration and solves residual moisture problems. Resistant to perforation and breakage. The bags are self-adhesive or heat-sealed and do not generate particles when opened.
Surgical Molded Ideal as a comfortable substitute for earloop face masks, this mask is a simple physical barrier ideal for exams and visitations or for dry, short procedures that do not produce fluid, spray or aerosols. LOW PERFORMANCE BFE= 98.7% at 4.2 microns Splash resistant barrier Flared edge prevents irritation Soft, flexible nose piece Not made with natural rubber latex…
The Power of Innovation. For better Sterilization Systec D Series Horizontal front loading bench-top autoclave One door These autoclaves don’t just seem to be different; they are different. Specially developed for sterilization applications in the laboratory, processes become easier, safer, more precise, reproducible and validatable.
The Power of Innovation. For better Sterilization Systec D Series Horizontal front loading double door autoclave Systec Serie-D 2D These autoclaves don’t just seem to be different; they are different. Specially developed for sterilization applications in the laboratory, processes become easier, safer, more precise, reproducible and validatable.
The Power of Innovation. For better Sterilization Systec V Series Vertical loading autoclave These autoclaves don’t just seem to be different; they are different. Specially developed for sterilization applications in the laboratory, processes become easier, safer, more precise, reproducible and validatable.